Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev. cuba. estomatol ; 56(3): e1989, jul.-set. 2019. tab
Artículo en Inglés | LILACS | ID: biblio-1093228

RESUMEN

ABSTRACT Introduction: Posts and core are frequently used in endodontically treated teeth with excessive loss of coronal tooth structure. Objective: To evaluate the effectiveness of self-adhesive cements under different pre-treatments of dentin in the resistance to extrusion of fiberglass posts. Methods: An experimental in vitro study was conducted. The randomly selected sample was 56 extracted bovine incisors with mature apices and without root curvature. Before the cementing procedure, pretreatment of dentin was performed with 11.5 percent polyacrylic acid, 17 percent EDTA or sodium hypochlorite. The type of failure between the post/cement/dentin was evaluated by stereomicroscope. Two hundred and sixteen bovine dentin discs were used. The disks were approximately 1 mm thick, and were obtained from 72 bovine roots restored with intraradicular retentions. Data were analyzed for better comprehension in an SPSS database for Windows version 15. Results: The highest values were found in groups G3, G4 and G5, and there was no bond strength significant difference in group G2. Conclusions: The pre-treatment had no effect on dentin bond strength, and the self-adhesive cement RelyX U100 appears to be a viable option in the cementation of fiber posts(AU)


RESUMEN Introducción: Los postes y el núcleo se utilizan con frecuencia en los dientes tratados endodónticamente con una pérdida excesiva de la estructura dental coronal. Objetivo: Evaluar la efectividad de los cementos autoadhesivos bajo diferentes pretratamientos de dentina en la resistencia a la extrusión de postes de fibra de vidrio. Métodos: Se realizó una investigación experimental in vitro en 56 dientes de ganado seleccionados al azar con cierre apical maduro y sin curvaturas radiculares. Antes del procedimiento de cementación, se llevó a cabo el pretratamiento de la dentina con 11,5 por ciento de ácido poliacrílico, 17 por ciento de EDTA o hipoclorito de sodio. El estereomicroscopio evaluó el tipo de falla entre el poste / cemento / dentina. Se usaron 216 discos de dentina bovina. Los discos tenían aproximadamente 1 mm de espesor y se obtuvieron de 72 raíces bovinas restauradas con retenciones intrarradiculares. Los datos se analizaron para una mejor comprensión en una base de datos de SPSS para Windows versión 15. Resultados: Los valores más elevados fueron encontrados en los grupos G3, G4 y G5 y no fue significativa la prueba de resistencia en el grupo G2. Conclusiones: El pretratamiento no tuvo efecto sobre la fuerza de unión dentinaria, y el cemento autoadhesivo RelyX U100 parece ser una opción viable en la cementación postes de fibra(AU)


Asunto(s)
Humanos , Diente no Vital/epidemiología , Cementos de Resina/efectos adversos , Resistencia Flexional/fisiología
2.
Int. j. odontostomatol. (Print) ; 11(3): 347-352, set. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-893272

RESUMEN

ABSTRACT: The purpose of this study was to investigate the accuracy and interobserver reliability of examiners with different levels of clinical experience, when diagnosing radiographic proximal caries lesions. Bitewing radiographs were selected from a patient attending Operative Dentistry Clinic, Universidad de Chile. Radiographic examination was performed by three different groups: A: third year dentistry students, B: fourth year dentistry students, and C: dentist recently graduated. Thirty-two proximal surfaces were scored as: 0, sound; 1: enamel caries; and 2: dentinal caries. The data were analysed and accuracy and interexaminer reliability were calculated. Accuracy values for enamel caries were: A (0.54), B (0.55) and C (0.58), and dentinal caries were: A (0.55), B (0.61) and C (0.63). Interexaminer reliability denoted marginal agreement for all groups, A (0.249), B (0.213) and C (0.282) for enamel caries and A (0.058), B (0.102), and C (0.344) for dentinal caries. The results of this study indicate that the accuracy and interexaminer reliability of bitewing radiographic examination were influenced by the clinical experience when detecting radiographic proximal caries, however low values of accuracy and interexaminer reliability were noted, reinforcing the necessity of improving education and training in radiographic caries detection.


RESUMEN:El objetivo de este trabajo fue evaluar la precisión y concordancia entre examinadores con distinto nivel de experiencia clínica, al diagnosticar lesiones de caries proximales en radiografías. Un set de radiografías bitewing fue seleccionado de un paciente que acudió a la Clínica de Operatoria de la Facultad de Odontología, Universidad de Chile. El examen radiográfico fue realizado por tres grupos distintos: A: estudiantes de Odontología de tercer año, B: estudiantes de Odontología de cuarto año, y C: dentistas recientemente graduados. Treinta y dos superficies proximales fueron analizadas y evaluadas como: 0, sana; 1: lesión de caries de esmalte, 2: lesión de caries dentinaria. Los datos obtenidos fueron analizados y la precisión y concordancia entre examinadores fueron calculadas. Los valores de precisión en lesiones de esmalte fueron: A (0,54), B (0,55) y C (0,58), y para lesiones dentinarias fueron: A (0,55), B (0,61) y C (0,63). La concordancia entre examinadores denotó ser marginal para todos los grupos, A (0,249), B (0,213) y C (0,282) en lesiones de esmalte y A (0,058), B (0,102), y C (0,344) en lesiones dentinarias. Los resultados de este estudio indican que la precisión y la concordancia entre examinadores está influenciada por la experiencia clínica, sin embargo los valores encontrados fueron bajos, lo que refuerza la necesidad de mejorar la educación y entrenamiento en detección de lesiones de caries en radiografías


Asunto(s)
Humanos , Masculino , Adulto , Caries Dental/diagnóstico por imagen , Transiluminación , Curva ROC , Radiografía de Mordida Lateral , Ultrasonografía , Sensibilidad y Especificidad , Caries Dental/diagnóstico , Tomografía de Coherencia Óptica , Tomografía Computarizada de Haz Cónico
3.
Artículo en Inglés | LILACS | ID: biblio-900290

RESUMEN

ABSTRACT: Aim: To evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of experimental brackets bonded with self-adhesive resin cement. Ninety bovine teeth were randomly distributed (n = 15) according to the groups: G1 - metal brackets bonded with Transbond™ XT; G2 - APC metal brackets bonded without additional adhesive system; G3 - APC metal brackets bonded with self-etching adhesive system; G4 - metal brackets bonded with RelyXU200; G5 - experimental brackets bonded with Transbond™ XT; G6 - experimental brackets bonded with RelyXU200. Shear bond strength test of the brackets was carried out and after their removal, the ARI was observed. Results: The highest mean value of SBS was found in group 1 (14.33 MPa) and lower mean SBS has been in group 4 (2.36 MPa). The mean values of SBS found in the experimental groups were higher compared to the non-modified brackets. The ARI analysis demonstrated that groups that received the phosphoric acid or selfetching primer (G1,G2,G3andG5) showed adhesive partially and fully adhered to the tooth. Greater amounts of remnants were adhered to the bracket in the experimental brackets, this minimizes the risk of damage to the tooth enamel since it requires minimal finishing. These results suggest that the experimental brackets are interesting options for future use in orthodontics, since it has sufficient adhesive strength to the orthodontic treatment, and less risk of damage to the enamel at the time of removal of the brackets, and is a simple and inexpensive alternative.


Asunto(s)
Animales , Bovinos , Soportes Ortodóncicos , Cementos de Resina/química , Resistencia al Corte , Estrés Mecánico , Ensayo de Materiales , Adhesividad , Desconsolidación Dental , Cementos Dentales/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...